BP Southern Africa · full LED conversion · 2017

Case study · Commercial & office

A full office conversion that halved the load and was built down the road

Client

BP Southern Africa

Location

South Africa

Installed

2017

Division

LED Solutions

Executive summary

BP Southern Africa converted every light source in its offices to LED in one programme, covering general lighting, emergency lighting, undercover parking and feature downlighting. The panels were manufactured locally to suit the working environment and the illuminance levels required under occupational safety regulation. Annual lighting consumption fell from an estimated 124,256 kWh to 52,670 kWh, a reduction of about 58%, avoiding an estimated 74 tonnes of CO₂e a year. All figures on this page are estimates.

71586kWh

Energy saved per year
(estimated)

58.0%

Reduction in lighting
energy (estimated)

74tCO₂e

Carbon avoided per
year (estimated)

Figures are estimates derived from project close-out data and standard operating assumptions. They will vary with tariff, run hours and site conditions, and are indicative of this project rather than a guarantee of results on another site.

The project

What the site needed, and what we did

The client is a large institutional owner and investor in commercial property, and the brief came with a property owner's logic rather than a tenant's: the building had to be upgraded once, properly, to a standard that would hold for the asset's remaining life. That ruled out the piecemeal lamp-for-lamp replacement that most office retrofits settle for.

It also meant the scope could not stop at the areas people notice. Emergency lighting in stairwells, IP-rated fittings in undercover parking and downlighting in reception and boardrooms all had to be brought across in the same programme. The whole installation also had to satisfy the illuminance levels required under occupational safety regulation, verified with the client's appointed electrical engineer rather than asserted by the supplier.

How we solved it

We presented samples in consultation with the appointed electrical engineer before anything was specified, so the engineer signed off on fittings he had seen performing in the building rather than on a datasheet.

The panels were then manufactured in our own local factory to suit the working environment: 60 W in the 1200 × 600 aperture and 40 W in the 600 × 600, sized against the lux levels the regulations require for the tasks in each area. Local manufacture mattered for two reasons. The wattage and output could be set to the building rather than to whatever sat in a distributor's container, and both the original lead time and any future replacement got shorter.

IP65 fittings went into the undercover parking. LED bulkheads with integrated emergency gear went into the stairwells, so life-safety lighting was upgraded in the same programme instead of being left as a legacy island. GU10 LED downlighters were used in reception and the boardrooms, where appearance carries as much weight as output.

AreaLegacy installationLamphouse specification
Open-plan officesFluorescent troffersLocally manufactured LED panel, 1200 × 600, 60 W
Cellular offices & meeting roomsFluorescent troffersLocally manufactured LED panel, 600 × 600, 40 W
StairwellsLegacy fittings with separate emergency gearLED bulkhead with integrated emergency gear
Undercover parkingUnrated fluorescent battensIP65-rated LED fittings
Reception & boardroomsHalogen GU10 downlightersLED GU10 downlighters

Why it worked

What made the difference

Made here, sized here

Panels were built in our own factory to the wattages the building needed, not the wattages a container happened to hold. Replacements come from the same line.

Emergency lighting included

Stairwell bulkheads with integrated emergency gear were part of the same programme. Life-safety lighting is where retrofits most often get left behind.

Signed off by the engineer

Samples were presented to the client's appointed electrical engineer and specified against occupational safety illuminance requirements, not against a brochure.

Carried forward

What we would tell the next client

The scope decision is the one worth repeating. Because emergency lighting, parking and feature downlighting were pulled into the same programme, the building has no legacy islands left to trip over at the next refurbishment. Retrofits that stop at the ceiling grid always come back.

Supporting references

  1. [1]International Energy Agency, The next wave of LED lighting · https://www.iea.org/reports/the-next-wave-of-led-lighting
  2. [2]DFFE, Grid Emission Factors Report · https://www.dffe.gov.za
  3. [3]Eskom Data Portal · https://www.eskom.co.za/dataportal/

Got a site where the
lighting isn't earning its keep?

Tell us the areas, the hours they run, the lux you need to hit and your capex envelope. We'll come back inside the week with a design, a fitting schedule and a payback model.

Related: Commercial & office LED